Out Of Stock
Notify me when its in stock
Basic |
|
[Icw] Rated Short-Time Withstand Current |
1100 A -De <40 °C - 1 S for Signaling Circuit |
250 A -De <40 °C - 10 S For Power Circuit |
|
550 A -De <40 °C - 10 S For Power Circuit |
|
950 A -De <40 °C - 10 S For Power Circuit |
|
[Ie] Rated Operational Current |
For 200 A 60 °C) -De <= 440 V Ac Ac-1 Power Circuit |
[Ith] Classic Open Air Thermic Current |
For 200 A -De <60 °C Signaling Circuit |
[Ue] Rated Operational Voltage |
Power Circuit: <= 1000 V Ac 25...400 Hz |
Power Circuit: <= 460 V Dc |
|
[Ui] Rated Insulation Voltage |
Power Circuit: 1000 V ‘EConforming toıec 60947-4-1 |
Power Circuit: 600 V CSA certificated |
|
Power Circuit: 600 V UIcertificated |
|
[Uimp] Rated Impulse Withstand Voltage |
8 Kv 'E Conforming to IEC 60947 |
Overvoltage Category |
Iıı |
Terminals |
Power Circuit: Connector 1 Cable(s) 10-120 Mm²flexible |
Power Circuit: Connector 1 Cable(s) 10-120 Mm²flexible Cable Jagless |
|
Power Circuit: Connector 1 Cable(s) 10-120 Mm²Solid Cable Jagless |
|
Power Circuit : Connector 2 Cable(s) 10-50 Mm² flexible |
|
Power Circuit: Connector 2 Cable(s) 10-50 Mm² flexible Cable Jagless |
|
Power Circuit: Connector 2 Cable(s) 10-50 Mm² Solid Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-2.5 Mm²flexible |
|
Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-2.5 Mm²Solid Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible |
|
Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²Solid Cable Jagless |
|
Operating Time |
20…50 Msn Closing |
6…20 Msn Opening |
|
Electric Durability |
0.8 Mcycles 200 A Ac-1 Ue'De <= 440 V |
Contactor Application |
Resistor Load |
Control Circuit Voltage |
24 V Ac 50/60 Hz |
Control Circuit Type |
Ac -De 50/60 Hz |
Protective Cover |
Yes |
Usage Category |
Ac-1 |
Power distribution per Pole |
24 W Ac-1 |
Fixing Pole Contact |
4 Na |
Pole Description |
4P |
Maximum Operating Rate |
2400 Cyc/H -De <60 °C |
Mechanical Durability |
8 Mcycles |
Montage Support |
Plate Block |
Rail |
|
Average impedance |
0.6 Mohm - Ith 200 A 50 Hz For Power Circuit |
Series |
Tesys |
Tightening Torque |
Power Circuit: 12 N.M - Above Connector Hexagon 4 Mm |
Power Circuit: 1.2 N.M - Above Screw Clamp Terminals - with Screw Driver Philips No 2 |
|
Control Circuit: 1.2 N.M - Above Screw Clamp Terminals - with Screwdriver Philips No 2 |
|
Standarts |
Csa C22.2 No 14 |
En 60947-4-1 |
|
En 60947-5-1 |
|
Iec 60947-4-1 |
|
Iec 60947-5-1 |
|
Ul 508 |
|
Product Name |
Tesys D |
Product Group |
Lc1D |
Product Series |
Tesys D |
Product Certificates |
Bv |
Ccc |
|
Csa |
|
Dnv |
|
Gl |
|
Gost |
|
Lros (Lloyds Register Of Shipping) |
|
Rına |
|
Ul |
|
Product or Unit Type |
Contactor |
Fixing Auxiliary Contact |
1 Na + 1 Nk |
Features |
|
Flame Vetarder |
V1 'E Conforming to Ul 94 |
Ambient Air Condition for Operating |
-40-60 °C |
60-70 °C with derating |
|
Operating altitude |
0...3000 M |
Environmental Characteristic for Storage |
-60-80 °C |
Depth |
132 Mm |
Width |
150 Mm |
IP Protection Degree |
Ip20 Front 'E Conforming to Iec 60529 |
Pollution Degree |
3 |
Preventive Maintenance |
Th 'E Conforming to Iec 60068-2-30 |
Mechanical Robustness |
Shocks Contactor Open: 11 Msn for 10 Gn |
Shocks Contactor Close: 11 Msn for 15 Gn |
|
Vibrations Contactor Open: 2 Gn, 5...300 Hz |
|
Vibrations Contactor Close: 4 Gn, 5...300 Hz |
|
Product Weight |
2.86 Kg |
Fire Endurance |
850 °C 'E Conforming to IEC 60695-2-1 |
Heigh |
158 Mm |
General Features |
|
Bobin Technology |
Built-in bidirectional peak limiting diode suppressor |
Contactor Coil Voltage |
220 V Ac Standart |
Non-overlapping time |
In 1.5 Ms Blackout Power Between Nk and Na Contact |
In 1.5 Ms Energization Between Nk and Na Contact |
|
Power Range |
1.1-2 Kw -De 525-690 V 3 Phases |
2.2-3 Kw -De 380-440 V 3 Phases |
|
4-6 Kw -De 480-500 V 3 Phases |
|
4-6 Kw -De 525-690 V 3 Phases |
|
Heat Distribution |
3-8 W -De 50/60 Hz |
Contact Compatibility |
M14 |
Control Circuit Voltage Limits |
0,3...0,6 Uc -40-70 °C Reduce Ac 50/60 Hz |
0,8...1,15 Uc -40-55 °C Operating Ac 50 Hz |
|
1...1,5 Uc -55-70 °C Operating Ac 60 Hz |
|
Compatibility Code |
Lc1D |
Inrush Power in Va |
280-350 Va 50 Hz 0.8 20 °C |
280-350 Va 60 Hz 0.8 20 °C |
|
Hold Power Consumption in Va |
2-18 Va 50 Hz 0.3 20 °C) |
2-18 Va 60 Hz 0.3 20 °C) |