Temel

[Ie] Rated Operational Current

125 A 60 °C) -De <= 440 V Ac Ac-1 For Power Circuit

95 A 60 °C) -De <= 440 V Ac Ac-3 For Power Circuit

[Ue] Rated Operational Voltage

Power Circuit: <= 690 V Ac 50/60 Hz

Depth

121 Mm

Width

55 Mm

Contactor Application

Resister Load

Motor Control

Control Circuit Voltage

220 V Ac 50 Hz

Control Circuit Type

Ac -De 50 Hz

Usage Category

Ac-1

Ac-3

 Fixing Pole Contact

3 Na

[Ue] Rated Operational Voltage

3P

Motor Power Kw

25 Kw -De 220...230 V Ac 50/60 Hz

45 Kw -De 380...400 V

45 Kw -De 415 V

45 Kw -De 440 V

45 Kw -De 500 V

55 Kw -De 660...690 V

Color

Gray (Ral 7011)

Series

Easypact

Product Name

Easypact Tvs

Product Weigh

1.52 Kg

Product Series

Lc1E

Product or Unit Type

Contactor

Height

127 Mm

Features

Ambient Air Condition for Operating

-20-70 °C Uc'De

Operating altitude

3000 M Without

Environmental Characteristic for Storage

-60-80 °C

IP Protection Degree

Ip2X 'E Conforming to IEC  60529

Pollution Degree 

3

Preventive Maintenance

Th (Pollution Degree 3) 'E Conforming to IEC  60068

Mechanical Robustness

Shocks Condactor Open: 11 Msn For 6 Gn

Shocks Condactor Close: 11 Msn For 7 Gn

Vibrations Condactor Open: 1,5 Gn, 5...300 Hz

Vibrations Condactor Close: 3 Gn, 5...300 Hz

Rated Operating Ambient Temperature

-5-55 °C

Standards

Iec 60947-1

Iec 60947-4-1

Iec 60947-5-1

Ambient Air Condition for Operating

Eac

Operating altitude

850 °C 'E Conforming to IEC  60695-2-1

General Characteristic

[Icw] Rated Short-Time Withstand Current

135 A -De <40 °C - 600 S For Power Circuit

400 A -De <40 °C - 60 S For Power Circuit

800 A -De <40 °C - 10 S For Power Circuit

[Ui] Rated Insulation Voltage

690 V 'E Conforming to IEC  60947-4-1

[Uimp] Rated Impulse Withstand Voltage

6 Kv Bobin Power Circuitne Bağlı Değil 'E Conforming to IEC  60947

Overvoltage Category

Iıı

Connections - Terminals

Power Circuit: Screw Clamp Terminals 1 4-50 Mm² - Cable Hardness: FlexibleCable With Jag

Power Circuit: Screw Clamp Terminals 1 4-50 Mm² - Cable Hardness: Solid Cable Jagless

Power Circuit: Screw Clamp Terminals 2 4-16 Mm² - Cable Hardness: FlexibleCable With Jag

Power Circuit: Screw Clamp Terminals 2 4-50 Mm² - Cable Hardness: Solid Cable Jagless

Control Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: FlexibleCable With Jag

Control Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: FlexibleCable Jagless

Control Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: Solid Cable Jagless

Control Circuit: Screw Clamp Terminals 2 1-2.5 Mm² - Cable Hardness: FlexibleCable With Jag

Control Circuit: Screw Clamp Terminals 2 1-4 Mm² - Cable Hardness: FlexibleCable Jagless

Control Circuit: Screw Clamp Terminals 2 1-4 Mm² - Cable Hardness: Solid Cable Jagless

Non-overlapping time

1.5 Ms Blackout Power Between Nk and Na Contact Warranted

1.5 Ms Blackout Power Between Nk and Na Contact Warranted

Operating Time

20...35 Msn Closing

6...30 Ms Opening

Electric Durability

350000 Cycles Ac-1

900000 Cycles Ac-3

Irms Rated Closing Capacity

950 A -De 440 V Ac For Power Circuit 'E Conforming to IEC  60947-4-1

Heat Distrubition

6-10 W For Control Circuit

Fuse Value

10 A Gg -De <= 690 V CoordinationType 1 For Control Circuit 'E Conforming to IEC  60947-5-1

160 A Gg -De <= 690 V CoordinationType 1 For Power Circuit

Irms Rated Closing Capacity

Operating: 0,85...1,1 Uc -De 50 Hz 55 °C)

Reduce: 0,3...0,6 Uc -De 50 Hz 55 °C)

Power distribution per Pole

12W Ac-3

7.2 W Ac-1

Maximum Operating Rate

1200 Cyc/H -De <60 °C

Mechanical Robustness

300000 Cycles

Minimum Switching Current

5 Ma For Control Circuit

Minimum Switching Voltage

17 V For Control Circuit

Montage Support

Din Rail

Plate Block

Rated Breaking Capacity 

760 A -De 440 V For Power Circuit 'E Conforming to IEC  60947

Average impedance

0.8 Mohm - Ith 110 A 50 Hz For Power Circuit

Tightening Torque

Power Circuit: 12 N.M

Control Circuit: 1.2 N.M

Inrush Power in Va 

200-200 Va 50 Hz 0.75 20 °C)

220-220 Va 60 Hz 0.75 20 °C)

Hold Power Consumption in Va 

20-20 Va 50 Hz 0.3 20 °C)

22-22 Va 60 Hz 0.3 20 °C)

İnsulation Resistance

> 10 Mohm For Control Circuit

Auxiliary Contact Fixing

1 Na + 1 Nk

 

Dimensions(cm)
15.2 x 15.8 x 11.5
Weight(Kg)
1.6