Out Of Stock
Notify me when its in stock
Temel |
|
[Ie] Rated Operational Current |
12 A 60 °C) -De <= 440 V Ac Ac-3 For Power Circuit |
25 A 60 °C) -De <= 415 V Ac Ac-1 For Power Circuit |
|
[Ue] Rated Operational Voltage |
Power Circuit: <= 690 V Ac 50/60 Hz |
Depth |
80 Mm |
Width |
45 Mm |
Contactor Application |
Resister Load |
Motor Control |
|
Control Circuit Voltage |
220 V Ac 50 Hz |
Control Circuit Type |
Ac -De 50 Hz |
Usage Category |
Ac-1 |
Ac-3 |
|
Pole Contact Fixing |
3 Na |
[Ue] Rated Operational Voltage |
3P |
Motor Power Kw |
3 Kw -De 220...230 V Ac 50/60 Hz (Ac-3) |
5.5 Kw -De 380...400 V Ac 50/60 Hz (Ac-3) |
|
5.5 Kw -De 415 V Ac 50/60 Hz (Ac-3) |
|
5.5 Kw -De 440 V Ac 50/60 Hz (Ac-3) |
|
7.5 Kw -De 500 V Ac 50/60 Hz (Ac-3) |
|
7.5 Kw -De 660...690 V Ac 50/60 Hz (Ac-3) |
|
Color |
Gray (Ral 7011) |
Series |
Easypact |
Product Name |
Easypact Tvs |
Product Weight |
0.3 Kg |
Product Series |
Lc1E |
Product or Unit Type |
Contactor |
Height |
74 Mm |
Features |
|
Ambient Air Condition for Operating |
-20-70 °C Uc'De |
Operating altitude |
3000 M Without |
Environmental Characteristic for Storage |
-60-80 °C |
IP Protection Degree |
Ip2X 'E Conforming to IEC 60529 |
Pollution Degree |
3 |
Preventive Maintenance |
Th (Pollution Degree 3) 'E Conforming to IEC 60068 |
Mechanical Robustness |
Shocks Contactor Open: 11 Msn For 6 Gn |
Shocks Contactor Close: 11 Msn For 7 Gn |
|
Vibrations Contactor Open: 1,5 Gn, 5...300 Hz |
|
Vibrations Contactor Close: 3 Gn, 5...300 Hz |
|
Rated Operating Ambient Temperature |
-5-55 °C |
Standards |
Iec 60947-1 |
Iec 60947-4-1 |
|
Iec 60947-5-1 |
|
Ambient Air Condition for Operating |
Eac |
Operating altitude |
850 °C 'E Conforming to IEC 60695-2-1 |
General Characteristic |
|
[Icw] Rated Short-Time Withstand Current |
105 A -De <40 °C - 600 S For Power Circuit |
30 A -De <40 °C - 60 S For Power Circuit |
|
61 A -De <40 °C - 10 S For Power Circuit |
|
[Ui] Rated Insulation Voltage |
690 V 'E Conforming to IEC 60947-4-1 |
[Uimp] Rated Impulse Withstand Voltage |
6 Kv The coil isn't connected to Power Circuit 'E Conforming to IEC 60947 |
Overvoltage Category |
Iıı |
Connections - Terminals |
Power Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: Flexible Cable with jag< |
Power Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: Solid Cable Jagless |
|
Power Circuit: Screw Clamp Terminals 2 1-2.5 Mm² - Cable Hardness: Flexible Cable With end |
|
Power Circuit: Screw Clamp Terminals 2 1-4Mm² - Cable Hardness: Solid Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: Flexible Cable With Jag |
|
Control Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: Flexible Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 1 1-4 Mm² - Cable Hardness: Solid Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 2 1-2.5 Mm² - Cable Hardness: Flexible Cable With Jag |
|
Control Circuit: Screw Clamp Terminals 2 1-4 Mm² - Cable Hardness: Flexible Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 2 1-4 Mm² - Cable Hardness: Solid Cable Jagless |
|
Non-overlapping time |
1.5 Ms Blackout Power Between Nk and Na Contact Warranted |
1.5 Ms Blackout Power Between Nk and Na Contact Warranted |
|
Operating Time |
12...22 Msn Closing |
4…19 Ms Opening |
|
Electric Durability |
1400000 Cycles Ac-1 |
300000 Cycles Ac-3 |
|
Irms Rated Closing Capacity |
120 A -De 440 V Ac For Power Circuit 'E Conforming to IEC 60947-4-1 |
Heat Distrubition |
2-3 W For Control Circuit |
Fuse Value |
10 A Gg -De <= 690 V Coordination Type 1 For Control Circuit 'E Conforming to IEC 60947-5-1 |
25 A Gg -De <= 690 V Coordination Type 1 For Power Circuit |
|
Irms Rated Closing Capacity |
Operating: 0,85...1,1 Uc -De 50 Hz 55 °C) |
Reduce: 0,3...0,6 Uc -De 50 Hz 55 °C) |
|
Power distribution per Pole |
0.36 W Ac-3 |
1.6 W Ac-1 |
|
Maximum Operating Rate |
1800 Cyc/H -De <60 °C |
Mechanical Robustness |
10000000 Cycles |
Minimum Switching Current |
5 Ma For Control Circuit |
Minimum Switching Voltage |
17 V For Control Circuit |
Montage Support |
Din Rail |
Plate Block |
|
Rated Breaking Capacity |
200 A -De 440 V For Power Circuit 'E Conforming to IEC 60947 |
Average impedance |
2.5 Mohm - Ith 60 A 50 Hz For Power Circuit |
Tightening Torque |
Power Circuit: 1.2 N.M |
Control Circuit: 1.5 N.M |
|
Inrush Power in Va |
95-95 Va 60 Hz 0.75 20 °C) |
95-95 Va 50 Hz 0.75 20 °C) |
|
Hold Power Consumption in Va |
8.5-8.5 Va 60 Hz 0.3 20 °C) |
8.5-8.5 Va 50 Hz 0.3 20 °C) |
|
Insulation Resistance |
> 10 Mohm For Control Circuit |
Auxiliary Contact Fixing |
1 Nk |