Basic |
|
[Icw] Rated Short-Time Withstand Current |
100 A - 1 S for Signaling Circuit |
105 A -De <40 °C - 10 S For Power Circuit |
|
120 A - 500 Ms for Signaling Circuit |
|
140 A - 100 Ms For Signaling Circuit |
|
210 A -De <40 °C - 1 S For Power Circuit |
|
30 A -De <40 °C - 10 Min For Power Circuit |
|
61 A -De <40 °C - 1 Min For Power Circuit |
|
[Ie] Rated Operational Current |
25 A 60 °C) -De <= 440 V Ac Ac-1 For Power Circuit |
9 A 60 °C) -De <= 440 V Ac Ac-3 For Power Circuit |
|
[Ith] Classic Open Air Thermic Current |
10 A -De <60 °C For Signaling Circuit |
25 A -De <60 °C For Power Circuit |
|
[Ue] Rated Operational Voltage |
Power Circuit: <= 690 V Ac 25...400 Hz |
[Ui] Rated Insulation Voltage
|
Power Circuit: 690 V 'E Conforming to ıec 60947-4-1 |
Signaling Circuit: 690 V 'E Conforming to ıec 60947-1 |
|
[Uimp] Rated Impulse Withstand Voltage |
6 Kv 'E Conforming toıec 60947 |
Overvoltage Category |
Iıı |
Terminals
|
Power Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible |
Power Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible Cable Jagless |
|
Power Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²Solid |
|
Power Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible |
|
Power Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm² solid |
|
Power Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²flexible |
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible |
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²flexible Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 1 Cable(s) 1-4 Mm²Solid |
|
Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-2.5 Mm²flexible |
|
Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²flexible Cable Jagless |
|
Control Circuit: Screw Clamp Terminals 2 Cable(s) 1-4 Mm²Solid |
|
Coil Type |
Ac/Dc Electronic |
Operating Time |
45...55 Msn Closing |
20...90 Msn Opening |
|
Electric Durability |
0.6 Mcycles 25 A Ac-1 Ue'De <= 440 V |
2,4 Mcycles 9 A Ac-3 Ue'De <= 440 V |
|
Level of Reliability Safety |
B10D = 1369863 Cycles Rated Load Contactor 'E Conforming to En/Iso 13849-1 |
B10D = 20000000 Cycles Mechanical Load Contactor 'E Conforming to En/Iso 13849-1 |
|
Irms Rated Closing Capacity |
For 140 A Ac Signaling Circuit 'E Conforming to Iec 60947-5-1 |
For 250 A Dc Signaling Circuit 'E Conforming to Iec 60947-5-1 |
|
For 250 A -De 440 V Power Circuit 'E Conforming to Iec 60947 |
|
Fuse Value |
For 10 A Gg Signaling Circuit 'E Conforming to Iec 60947-5-1 |
For Coordination Type 2 20 A Gg -De <= 690 V Power Circuit |
|
For Coordination Type 1 25 A Gg -De <= 690 V Power Circuit |
|
Contactor Application |
Resistor Load |
Motor Control |
|
Control Circuit Voltage
|
24...60 V Ac 50/60 Hz |
24...60 V Dc |
|
Control Circuit Type |
Ac/Dc -De 50/60 Hz Ac/Dc Electronic |
Protective Cover |
Yes |
Usage Category |
Ac-1 |
Ac-3 |
|
Ac-4 |
|
Power distribution per Pole |
0.2 W Ac-3 |
1.56 W Ac-1 |
|
Fixing Pole Contact |
3 Na |
Pole Description |
3P |
Maximum Operating Rate |
3600 Cyc/H -De <60 °C |
Mechanical Durability |
15 Mcycles |
Montage Support |
Plate Block |
Rail |
|
Motor Power Hp |
For 0.33 Hp -De 115 V Ac 50/60 Hz 1 Phase Motors |
For 1 Hp -De 230/240 V Ac 50/60 Hz 1 Phase Motors |
|
For 2 Hp -De 200/208 V Ac 50/60 Hz 3 Phases Motors |
|
For 2 Hp -De 230/240 V Ac 50/60 Hz 3 Phases Motors |
|
For 5 Hp -De 460/480 V Ac 50/60 Hz 3 Phases Motors |
|
For 7.5 Hp -De 575/600 V Ac 50/60 Hz 3 Phases Motors |
|
Motor Power Kw |
2.2 Kw -De 220...230 V Ac 50/60 Hz (Ac-3) |
2.2 Kw -De 400 V Ac 50/60 Hz (Ac-4) |
|
4 Kw -De 380...400 V Ac 50/60 Hz (Ac-3) |
|
4 Kw -De 415...440 V Ac 50/60 Hz (Ac-3) |
|
5.5 Kw -De 500 V Ac 50/60 Hz (Ac-3) |
|
5.5 Kw -De 660...690 V Ac 50/60 Hz (Ac-3) |
|
Rated Breaking Capacity |
250 A -De 440 V For Power Circuit 'E Conforming to Iec 60947 |
Average impedance |
2.5 Mohm - Ith 25 A 50 Hz For Power Circuit |
Series |
Tesys |
Tightening Torque |
Power Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screwdriver flat Ø 6 Mm |
Power Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screw Driver Philips No 2 |
|
Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - with Screwdriver flat Ø 6 Mm |
|
Control Circuit: 1.7 N.M - Above Screw Clamp Terminals - Screwdriver Philips No 2 |
|
Standarts |
Csa C22.2 No 14 |
En 60947-4-1 |
|
En 60947-5-1 |
|
Iec 60947-4-1 |
|
Iec 60947-5-1 |
|
Ul 508 |
|
Product Name |
Tesys D |
Product Group |
Lc1D |
Product Series |
Tesys D |
Product Certificates |
Bv |
Ccc |
|
Csa |
|
Dnv |
|
Gl |
|
Gost |
|
Lros (Lloyds Register Of Shipping) |
|
Rına |
|
Ul |
|
Product or Unit Type |
Contactor |
Fixing Auxiliary Contact |
1 Na + 1 Nk |
Features |
|
Flame Vetarder |
V1 'E Conforming to Ul 94 |
Ambient Air Condition for Operating |
-40-60 °C |
60-70 °C with derating |
|
Operating altitude |
0...3000 M |
Environmental Characteristic for Storage |
-60-80 °C |
Depth |
86 Mm |
Width |
45 Mm |
IP Protection Degree |
Ip20 Front 'E Conforming to Iec 60529 |
Pollution Degree |
3 |
Preventive Maintenance |
Th 'E Conforming to Iec 60068-2-30 |
Mechanical Robustness |
Shocks Contactor Open: 11 Msn for 10 Gn |
Shocks Contactor Close: 11 Msn for 15 Gn |
|
Vibrations Contactor Open: 2 Gn, 5...300 Hz |
|
Vibrations Contactor Close: 4 Gn, 5...300 Hz |
|
Color |
Gray (Se Grey 6) |
Green (Se Green 2) |
|
Product Weight |
0,368Kg |
Fire Endurance |
850 °C 'E Conforming to IEC 60695-2-1 |
Heigh |
77 Mm |
General Features |
|
Coil Technology |
Built-İn Bidirectional Peak Limiting |
Non-overlapping time |
In 1.5 Ms Blackout Power Between Nk and Na Contact |
In 1.5 Ms Energization Between Nk and Na Contact |
|
Power Range |
1.1-2 Kw -De 200-240 V 3 Phase |
2.2-3 Kw -De 380-440 V 3 Phase |
|
4-6 Kw -De 380-440 V 3 Phase |
|
4-6 Kw -De 480-500 V 3 Phase |
|
Heat Distribution |
0.6-0.6 W -De 50/60 Hz |
Control Circuit Voltage Limits |
<= 0.1 Uc -40-70 °C Reduce Ac DC |
0,8...1,1 Uc -40-60 °C Operating DC |
|
0,85...1,1 Uc -40-60 °C Operating AC |
|
1...1.1 Uc 60-70 °C Operating Ac/Dc |
|
Minimum Switching Current |
For 5 Ma Signaling Circuit |
Minimum Switching Voltage |
For 17 V Signaling Circuiti |
Motor Starter Type |
Direct On-Line Contactor |
Signaling Circuit Frequency |
25...400 Hz |
Compatibility Code |
Lc1D |
Inrush Power in Va |
15-15 Va 50/60 Hz 20 °C) |
Hold Power Consumption in Va |
0.9-0.9 Va 20 °C) 50/60 Hz |
Hold Power Consumption in W |
0.6-0.6 W -De 20 °C |
Inrush Power in W |
14-14 W -De 20 °C |
Insulation Resistance |
For > 10 Mohm Signaling Circuit |
Auxiliary Contact Type
|
Type is Mirror Contact 1 Nk 'E Conforming to IEC 60947-4-1 |
Type is connected as mechanical 1 Na + 1 Nk 'E Conforming to Iec 60947-5-1 |